Part Number Hot Search : 
F1012 MC339 HC373 CZRB2039 RT114730 AI325 ADP5585 R2K10V5
Product Description
Full Text Search
 

To Download GPC140-28 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  56 condor d.c. power supplies, inc., 2311 statham parkway, oxnard, ca 93033 800-235-5929 ? 805-486-4565  fax 805-487-8911  www.condorpower.com gpc140 commercial/ gpm140 medical 140 watt global performance switchers specifications: ac input 85-264 vac, 47-63 hz single phase. input current maximum input current at 120 vac, 60 hz with full rated output load: 3.7 a hold-up time 20ms minimum from loss of ac input at full load, nominal line (115 vac). output power 140 w convection; 160 w with air flow. peak ratings are for 60 s maximum duration, 10% duty cycle. overload protection fully protected against short circuit and output overload. short circuit protection is cycling type power limit on output 1. recovery after fault is automatic. overvoltage protection main outputs: 130% 15% typical. efficiency 70% at full rated load, nominal input voltage, depending on model and load distribution. input protection internal ac fuse provided. designed to blow only if a catastrophic failure occurs in the unit. inrush current inrush is limited by internal thermistors. inrush at 240 vac, averaged over the first ac half-cycle under cold start conditions will not exceed 60 a. temperature coefficient 0.03%/ c typical on all outputs. thermal shutdown provided as a standard feature. designed to protect unit from prolonged overtemperature. environmental designed for 0 to 50 c operation at full rated output power; derate output current and total output power by 2.5% per c above 50 c. see environmental and packaging specifications on next page. power fail ttl- or cmos-compatible output goes low (< 0.5 v) 5 ms before output voltage drops more than 4% below nominal voltage upon loss of ac power. the signal is factory set to trip on 84 to 94 vac brown-out depending upon incoming line impedance and distortion. other settings are available to the user through adjustment of built-in potentiometer. features:  wide-range ac input 85-264 vac  2-year warranty  conducted emi exceeds fcc class b and cispr 22 class b (commercial models) and cispr 11 class b (medical models)  single outputs  commercial approved to ul1950, iec950, en60950 and csa22.2-234 l3  medical approved to ul2601-1, iec601-1 and csa22.2 no. 601  marked to lvd output noise 0.5% rms, 1% pk-pk, 20 mhz bandwidth, differential mode. measured with noise probe directly across output terminals of the power supply. transient response main output ? 500 s typical response time for return to within 0.5% of final value for a 50% load step change. ? i/ ? t<0.2 a/s. maximum voltage deviation is 3.5%. startup/ shutdown overshoot less than 3%. remote sense provided as a standard feature. voltage adjustment built-in potentiometer adjusts voltage 5%. overload protection factory set to begin power limiting at approximately 175 w. emi/emc compliance all models include built-in emi filtering to meet the following emissions requirements: emi specifications compliance level conducted emissions gpc140 en55022 class b; fcc class b conducted emissions gpm140 en55011 class b; fcc class b static discharge en61000-4-2, 6 kv contact, 8 kv air rf field susceptibility en61000-4-3, 3 v/meter fast transients/bursts en61000-4-4, 2 kv, 5 khz surge susceptibility en61000-4-5, 1 kv diff., 2 kv com. commercial leakage current 0.95 ma 254 vac @ 60 hz input. commercial safety approved to ul1950, csa22.2 no. 234 level 3, iec950 and en60950. ul file #e135803 commercial; csa #lr46516 all models. the output(s) are intended for safety earthed signal output and intermediate circuits only. all dc outputs are selv under normal and single fault conditions. medical leakage current 60 a 254 vac @ 60 hz input. medical safety approved to ul2601, csa22.2 no. 601 level 3 and iec601. ul file e116994; csa #lr46516. the output(s) are intended for safety earthed signal output and intermediate circuits only. the output(s) are not accept- able for patient connection without additional isolation. all dc outputs are selv under normal and single fault conditions.
57 condor d.c. power supplies, inc., 2311 statham parkway, oxnard, ca 93033 800-235-5929  805-486-4565  fax 805-487-8911  www.condorpower.com gpc140 commercial/ gpm140 medical 140 watt multiple output gpc140/ gpm140 mechanical specifications l a i c r e m m o c l e d o m l a c i d e m l e d o m t u p t u o t u p t u o m u m i n i m t u p t u o ) b ( m u m i x a m t u p t u o ) c ( m u m i x a m k a e p p - p e s i o n ) a ( n o i t a l u g e r l a t o t 5 - 0 4 1 c p g 5 - 0 4 1 m p g v 5a 0a 6 2a 0 3a 2 3v m 0 5% 2 2 1 - 0 4 1 c p g 2 1 - 0 4 1 m p g v 2 1a 0a 7 . 1 1a 4 . 3 1a 6 . 4 1v m 0 2 1% 2 5 1 - 0 4 1 c p g 5 1 - 0 4 1 m p g v 5 1a 0a 3 . 9a 7 . 0 1a 7 . 1 1v m 0 5 1% 2 4 2 - 0 4 1 c p g 4 2 - 0 4 1 m p g v 4 2a 0a 8 . 5a 7 . 6a 3 . 7v m 0 4 2% 2 8 2 - 0 4 1 c p g 8 2 - 0 4 1 m p g v 8 2a 0a 5a 7 . 5a 3 . 6v m 0 8 2% 2 a. total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial vol tage setting, input line voltage and output load. b. unrestricted natural convection cooling. c. requires 26cfm moving air. a. units should be allowed to warm up/operate under non-condensing conditions before application of power. b. random vibration ? 10 to 2000hz, 6db/octave roll-off from 350 to 2000hz, 3 orthogonal axes. tested for 10 min./axis operating and 1 hr./axis non-operating. c. shock testing ? half-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes, total 6 shocks. l a t n e m n o r i v n e n o i t a c i f i c e p s g n i t a r e p o g n i t a r e p o - n o n ) a ( e r u t a r e p m e ts c e p s l a u d i v i d n i e e s5 8 + o t 0 4 - o c ) a ( y t i d i m u hh r % 5 9 o t 0h r % 5 9 o t 0 ) b ( k c o h sg 0 2 k p g 0 4 k p e d u t i t l at f 0 0 0 , 0 1 o t 0 0 5 -t f 0 0 0 , 0 4 o t 0 0 5 - ) c ( n o i t a r b i vg 5 . 1 s m r g 3 0 0 . 0 , 2 z h /g 5 s m r g 6 2 0 . 0 , 2 z h /


▲Up To Search▲   

 
Price & Availability of GPC140-28

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X